The Ricardo 150 kW diesel generator is listed with an R6113AZLD engine, 150 kW / 187.5 kVA prime and 165 kW / 206.25 kVA standby reference ratings at 50 Hz.
Request current data sheets, fuel-consumption and load-response data, installation details and written warranty terms for your project.
The Ricardo 150 kW diesel generator listed by Alexerpower / Weifang Junwei Machinery Co., Ltd uses a Ricardo R6113AZLD diesel engine. Its published 50 Hz electrical ratings are 150 kW / 187.5 kVA prime power and 165 kW / 206.25 kVA standby power, with three-phase voltage options, a power factor of 0.8 and a listed engine speed of 1500 rpm. Provide your operating duty, voltage and load list when requesting a configuration.
Prime and standby describe different duty ratings. The standby output should not be assumed available for continuous operation. Confirm the complete generator’s electrical rating separately from the engine shaft-power specification.
These reference data are reorganized from the existing Alexerpower product listing. Request current generator-set, R6113AZLD engine and alternator data sheets, rating conditions and the agreed scope of supply before ordering.
| Parameter | Listed specification |
|---|---|
| Prime electrical power | 150 kW / 187.5 kVA at 50 Hz |
| Standby electrical power | 165 kW / 206.25 kVA at 50 Hz |
| Frequency | 50 Hz |
| Listed voltage options | 440 V, 415 V, 400 V or 380 V; confirm the ordered voltage |
| Phases | Three-phase in the listing; confirm the supplied electrical configuration |
| Power factor | 0.8 |
| Engine model | Ricardo R6113AZLD |
| Air intake | Turbocharged in the listing; confirm the supplied engine version |
| Governor | Electronic or mechanical in the listing; confirm which governor and controller are supplied |
| Rated engine speed | 1500 rpm |
| Compression ratio | 16.5:1 listed; confirm the supplied engine data sheet |
| Oil capacity | 22 L listed; confirm the engine version and service fill |
| Coolant capacity | 36 L listed; confirm the supplied cooling-system capacity |
| Engine cooling | Closed water cooling in the listing; confirm the cooling-system specification |
| Alternator arrangement | Single-bearing |
| Alternator protection | IP23 mentioned in the listing; confirm the supplied alternator and enclosure specification |
| Alternator insulation | Class H listed; confirm the insulation and temperature-rise ratings |
| Listed steady-state voltage regulation | ±1% stated limit; confirm the operating range, load and test conditions |
| Listed steady-state frequency regulation | ≤5% as stated in the original listing; verify the definition, tolerance and governor test conditions |
| Listed transient frequency deviation | +10% / −7% figures in the listing; confirm the load step, tolerances and test conditions |
| Listed voltage stable time | ≤5 s reference; confirm the load step, acceptance band and test conditions |
| Listed frequency recovery time | ≤3 s reference; confirm the load step, acceptance band and test conditions |
| Radiator reference | 40°C maximum stated; confirm cooling performance for site temperature and ventilation |
| Charging equipment | 24 V charging alternator listed; confirm the complete starting and charging package |
| Electrical protection | Main line circuit breaker listed; confirm its rating and scope of supply |
Request the R6113AZLD engine’s current displacement, bore and stroke, cylinder arrangement and shaft-power rating from the actual supplied-model data sheet. Also request the complete generator-set model, installation drawing and approved transient voltage performance.
The existing listing includes the following options for enquiry. Confirm compatibility, equipment specifications and inclusion in the quotation:
The base description includes a belt-driven radiator fan with safety guard, vibration isolation, dry-type air filter, fuel filter and oil filter. Request the complete bill of materials and installation drawing for the quoted assembly.
The published ratings are 150 kW / 187.5 kVA prime and 165 kW / 206.25 kVA standby at 50 Hz and a power factor of 0.8. Confirm the approved duty definition, load profile, site conditions and operating limits for the quoted unit. Do not treat the standby value as continuous output or assume overload permission from the prime label.
The listing specifies three-phase 440 V, 415 V, 400 V or 380 V at 50 Hz, with a listed engine speed of 1500 rpm. Confirm the ordered voltage and electrical configuration. For 60 Hz or another voltage, request a separately approved engine-alternator combination, speed and electrical ratings rather than applying the 50 Hz values unchanged.
The current product information does not provide a verified L/h fuel-consumption curve. Request complete generator-set consumption at your intended load points, with fuel specification and test conditions, for operating-cost and fuel-tank planning. Fuel figures from another engine or generator configuration should not be used as this unit’s consumption.
These are listed as options, so confirm the actual scope of supply. Specify the ATS or parallel-operation sequence and required controller functions. For a soundproof enclosure, request noise data with the load, enclosure type and measurement distance stated.
The listing mentions electronic or mechanical governing; confirm which version is supplied and its controller compatibility. The original frequency limit and recovery times require defined test conditions. Request approved steady-state and transient voltage and frequency tolerances, load steps, acceptance bands and test reports, particularly for motor starting or sensitive loads.
Request written warranty terms with a clear start date, time and running-hour limits, coverage and exclusions. Ask for manuals, a factory test report and model-specific conformity or emissions documents required for your destination, together with the agreed spare-parts and service arrangements.
For industrial power or backup-power projects, provide the actual load and site data so the proposed 150 kW generator and control package can be assessed together:
The Cummins generator-set selection guide provides general background on duty ratings, load assessment and site conditions. Confirm this Ricardo assembly’s specification using its own approved data sheet.
Contact Alexerpower with your load list and project requirements. Request the current complete generator-set and R6113AZLD data sheets, alternator and governor details, electrical duty ratings, fuel-consumption data, installation drawing, current photographs, warranty terms and full scope of supply.