Ricardo 75 kW diesel generator, listed as JW R75GF with a Weifang Ricardo R6105ZD engine.
Send your load list, duty and site conditions to confirm the current specification, ATS or enclosure options and complete scope of supply.
The Ricardo 75 kW diesel generator from Alexerpower / Weifang Junwei Machinery Co., Ltd is listed as model JW R75GF with a Weifang Ricardo R6105ZD diesel engine. The published 50 Hz ratings are 75 kW / 93.75 kVA prime power and 82.5 kW / 103.13 kVA standby power, at a listed engine speed of 1500 rpm.
Use the prime and standby ratings according to the approved operating duty. Confirm the current generator-set data sheet, load requirements and site conditions before selecting the supplied configuration.
The table presents reference data from the existing Alexerpower listing. Confirm the engine and alternator nameplates, rating conditions and scope of supply in the quotation.
| Parameter | Listed specification |
|---|---|
| Generator-set model | JW R75GF |
| Prime electrical power | 75 kW / 93.75 kVA at 50 Hz |
| Standby electrical power | 82.5 kW / 103.13 kVA at 50 Hz |
| Frequency | 50 Hz |
| Listed voltage options | 440 V, 415 V, 400 V or 380 V; confirm the ordered voltage and phases |
| Engine | Weifang Ricardo R6105ZD |
| Rated engine speed | 1500 rpm |
| Engine construction | Six-cylinder, four-stroke, direct injection |
| Cooling system | Water-cooled; closed water cooling system listed |
| Air intake | Turbocharged in the existing description; verify the supplied engine version |
| Displacement | 6.49 L |
| Bore × stroke | 105 × 125 mm |
| Compression ratio | 16.0:1 |
| Specific fuel consumption | 224 g/kW·h at 100% load; request the measurement basis and test conditions |
| Listed oil capacity | 20 L |
| Listed coolant capacity | 23 L |
| Alternator arrangement | Single-bearing |
| Alternator protection | IP23 listed; confirm the supplied alternator model and enclosure |
| Alternator insulation | Class H |
| Radiator reference | 40°C maximum stated; confirm cooling performance for site temperature and ventilation |
| Charging equipment | 24 V charging alternator listed; confirm the complete starting package |
| Electrical protection | Main line circuit breaker listed; confirm its rating and included equipment |
The prime rating of 75 kW / 93.75 kVA corresponds to a power factor of 0.8. These are the complete generator set’s listed electrical ratings, not the engine shaft-power specification. The standby rating should not be treated as an approved continuous output.
The listing includes the following options for enquiry. Availability and compatibility must be confirmed for the selected engine, alternator and controller:
The listed base package describes a belt-driven radiator fan with safety guard, vibration isolation, dry-type air filter, fuel filter and oil filter. Confirm the exact bill of materials and installation drawing for the quoted unit.
The existing listing gives 75 kW / 93.75 kVA prime and 82.5 kW / 103.13 kVA standby at 50 Hz. Request the approved duty definition, permissible operating hours and load profile. Do not assume that the standby value is available for continuous operation.
No. kW describes active electrical power, while kVA describes apparent power. This page lists 75 kW as 93.75 kVA at a power factor of 0.8. Specify both the load power and power factor when discussing the generator size.
The published reference is 224 g/kW·h at 100% load, a specific fuel-consumption figure rather than a litres-per-hour value. Ask for complete generator-set consumption in L/h at your intended loads, with the fuel specification and test conditions, before estimating running cost or tank capacity.
This page’s power and speed data are for 50 Hz and 1500 rpm. The listed voltage options are 440 V, 415 V, 400 V and 380 V. For another voltage or 60 Hz, request a separately approved engine-alternator configuration and its corresponding ratings.
ATS, paralleling equipment and different installation formats are listed as options. Confirm which items are included in the quotation. For a soundproof configuration, request noise data with the load, enclosure type and measurement distance stated.
Request written warranty terms stating the start date, time and running-hour limits, coverage and exclusions. Also request the model-specific conformity or emissions documents required for your destination, together with manuals and the agreed spare-parts list.
For industrial equipment, site power or backup-power enquiries, send the running and starting loads so the proposed generator can be assessed for the actual project.
For background on ratings, site conditions and load assessment, see the Cummins generator-set selection guide. It explains general planning considerations; the supplied Ricardo unit’s approved data sheet governs its specification.
Contact Alexerpower with the information above. Ask for the current JW R75GF data sheet, engine and alternator model details, installation dimensions, fuel-consumption data, current photographs, warranty terms and complete scope of supply.
Request a 75 kW diesel generator quotation · sales@alexerpower.com · WhatsApp +86 151 6954 2396 · Call our sales team
Explore the diesel generator range and Ricardo 100 kW diesel generator, or read the natural gas vs diesel generator comparison. Compare confirmed duty ratings and project requirements when considering another configuration.
We will contact you within 1 working day, please pay attention to the email with the suffix “@alexerpower.com”.