Ricardo 250 kW Diesel Generator

Ricardo 250 kW diesel generator, listed as JWR250GF with a Ricardo JW10D288B engine.

  • 50 Hz prime rating: 250 kW / 312.5 kVA.
  • 50 Hz standby rating: 275 kW / 343.75 kVA.
  • Listed power factor and speed: 0.8 and 1500 rpm.
  • Voltage options: 440 V, 415 V, 400 V or 380 V; confirm the ordered voltage and phases.

Send your load list, duty and site conditions to confirm the current data sheet, ATS, paralleling or enclosure options and complete scope of supply.

Additional information

Product Details:

Ricardo 250 kW diesel generator overview

The Ricardo 250 kW diesel generator listed by Alexerpower / Weifang Junwei Machinery Co., Ltd is model JWR250GF with a Ricardo JW10D288B diesel engine. Its published 50 Hz electrical ratings are 250 kW / 312.5 kVA prime power and 275 kW / 343.75 kVA standby power, at a power factor of 0.8 and a listed engine speed of 1500 rpm.

Specify the required operating duty, voltage, phases and load profile when requesting a configuration. The prime and standby values describe different duty ratings; the standby output should not be assumed available for continuous operation.

250 kW diesel generator reference specifications

These reference data are reorganized from the existing Alexerpower product listing. Request the current generator-set, engine and alternator data sheets, rating conditions and agreed scope of supply before ordering.

JWR250GF with JW10D288B engine: published 50 Hz reference data
ParameterListed specification
Generator-set modelJWR250GF
Prime electrical power250 kW / 312.5 kVA at 50 Hz
Standby electrical power275 kW / 343.75 kVA at 50 Hz
Frequency50 Hz
Listed voltage options440 V, 415 V, 400 V or 380 V; confirm the ordered voltage and phases
Power factor0.8
Engine modelRicardo JW10D288B
Engine constructionSix-cylinder, four-stroke, direct injection
Air intakeTurbocharged in the listing; confirm the supplied engine version
Rated engine speed1500 rpm
Compression ratio16:1 listed; confirm the supplied engine data sheet
GovernorElectronic governor listed; confirm the governor and controller specification
Engine coolingWater-cooled
Alternator arrangementSingle-bearing
Alternator protectionIP23 mentioned in the listing; confirm the supplied alternator and enclosure specification
Alternator insulationClass H
Listed voltage regulation±0.5% reference; confirm the operating range, load and test conditions
Radiator reference40°C maximum stated; confirm cooling performance for site temperature and ventilation
Charging equipment24 V charging alternator listed; confirm the complete starting and charging package
Electrical protectionMain line circuit breaker listed; confirm its rating and scope of supply

Request the JW10D288B engine’s current displacement, bore and stroke, installation dimensions and shaft-power rating from the actual supplied-model data sheet. The complete generator’s electrical rating should be assessed separately from the engine shaft-power specification.

ATS, paralleling and enclosure options

The existing listing includes the following options for enquiry. Confirm the proposed equipment, compatibility and inclusion in the quotation:

  • Controls and switching: remote control panel, automatic transfer switch (ATS) and paralleling system. Describe standalone, backup or parallel operation and the required control functions.
  • Starting and electrical accessories: engine heater, battery charger, air preheater, alternator heater and PMG excitation. Confirm the package for the selected engine and alternator.
  • Installation format: rainproof, soundproof or trailer configuration. Provide the installation layout, noise limit and measurement distance.
  • Service items: request the agreed spare-parts list, maintenance documentation and service arrangements for the destination.

The base description includes a belt-driven radiator fan with safety guard, vibration isolation, dry-type air filter, fuel filter and oil filter. Ask for the complete bill of materials, installation drawing and access requirements.

Ricardo 250 kW diesel generator FAQ

What are the prime and standby ratings?

The listing gives 250 kW / 312.5 kVA prime and 275 kW / 343.75 kVA standby at 50 Hz and a power factor of 0.8. Confirm the approved duty definition, load profile, site conditions and operating limits for the quoted unit. Do not treat the standby rating as a continuous output.

Does the prime rating allow overload operation?

Do not assume overload permission from the prime power label alone. Request the manufacturer’s approved overload capacity, duration, duty conditions and protection settings for the complete unit. Motor starting and load-step requirements should be assessed using generator performance data.

Can I request another voltage or a 60 Hz version?

The published voltage options are 440 V, 415 V, 400 V or 380 V at 50 Hz. Confirm voltage and phases for the ordered unit. For 60 Hz or another voltage, request a separately approved engine-alternator configuration and corresponding ratings rather than applying the listed 50 Hz values unchanged.

How much diesel does this generator consume per hour?

The current product information does not provide a verified L/h fuel-consumption curve. Ask for complete generator-set consumption at your intended load points, with fuel specification and test conditions. Use that data and your operating schedule to discuss operating cost and the fuel-system requirements.

Are ATS, paralleling and a soundproof enclosure included?

These are listed as options, so confirm the actual scope of supply. For ATS or paralleling, specify the operating sequence and required functions. For an enclosure, request noise data with the load, enclosure type and measurement distance stated.

What warranty and certification documents should I request?

Request written warranty terms with a clear start date, time and running-hour limits, coverage and exclusions. Ask for manuals, a factory test report and model-specific conformity or emissions documents required for your destination, together with the agreed spare-parts and service arrangements.

Load and installation information for selection

For industrial power or backup-power projects, provide the actual load and site data so the proposed 250 kW generator and control package can be assessed together:

  1. Application, destination, quantity and desired delivery date.
  2. Required kW and kVA, voltage, phases, frequency, load list and largest motor starting load.
  3. Prime or standby duty, operating hours, load steps, starting sequence and permitted voltage or frequency variation.
  4. Site altitude, ambient temperature, cooling and ventilation, exhaust routing, installation space and noise requirements.
  5. ATS, remote controls, paralleling, enclosure or trailer, fuel-system and project-documentation requirements.

The Cummins generator-set selection guide provides general background on duty ratings, load assessment and site conditions. Confirm this Ricardo assembly’s specification using its own approved data sheet.

Request a Ricardo 250 kW diesel generator quotation

Contact Alexerpower with your load list and project requirements. Request the current JWR250GF and JW10D288B data sheets, alternator and control details, electrical duty ratings, fuel-consumption data, installation drawing, current photographs, warranty terms and full scope of supply.

Request a 250 kW diesel generator quotation · sales@alexerpower.com · WhatsApp +86 151 6954 2396 · Call our sales team

Explore the diesel generator range and Ricardo 200 kW diesel generator, or read our natural gas vs diesel generator comparison. Compare confirmed electrical duty ratings and load requirements when considering another configuration.

Ask For A Quote

We will contact you within 1 working day, please pay attention to the email with the suffix “@alexerpower.com”.